Article
Meta Description: Fire protection design for the 677-foot Mutual of Omaha Tower in Omaha — high-rise NFPA 13, NFPA 72, standpipe pressure zoning, and smoke control under IBC 2018.Section 1: Project OverviewThe Mutual of…
Article
Meta Description: Fire protection design for Vantage's Lighthouse campus in Port Washington, WI — 902 MW, four data center buildings, NFPA 13 (2019) and NFPA 72 (2019).Section 1: Project OverviewVantage Data Centers brok…
Article
Meta Description: Fire sprinkler and alarm systems are routinely submitted as deferred items under IBC Section 107.3.4.1. Here is what the code requires and where the process breaks down.On most commercial construction p…
Article
Meta Description: Fire protection requirements for a 12-story, 390-bed Level I trauma hospital under construction in northeast Houston. NFPA 101, NFPA 13, and NFPA 72 code analysis.Section 1: Project OverviewHarris Healt…
Article
Meta Description: Fire protection design for a 69-story, 775-foot luxury residential tower on Manhattan's Upper West Side under NYC Building Code 2022 and NFPA 13 (2016).Section 1: Project Overview50 West 66th Street is…
Article
Meta Description: NFPA 13-2022 overhauled its working drawing requirements. Here's what changed in Section 28.1.3 and how it intersects with BIM coordination workflows on commercial projects.IntroductionThere are two dis…
Article
Meta Description: Fire protection design for Equinix's $835M DA12 data center campus in West Dallas — NFPA 13, NFPA 72, NFPA 75, and the 2021 Dallas Fire Code.Section 1: Project OverviewEquinix is constructing a two-phas…
Article
Meta Description: A review of fire protection design requirements for Hillman Group's 715,000-sq-ft distribution center under construction in Forest Park, Ohio, including NFPA 13 (2022).Section 1: Project OverviewOn June…
Article
Meta Description: Fire protection design requirements for 400 Lake Shore, a 72-story, 875-foot residential tower under construction in Chicago's Streeterville neighborhood.Section 1: Project Overview400 Lake Shore is a t…
Article
Meta Description: What AHJs check in fire alarm and sprinkler submittals — code editions, complete documentation, first-pass rejection triggers, and how to manage the review.The Authority Having Jurisdiction—the AHJ—is t…
Article
Meta Description: Fire protection design requirements for University Health's $550M Palo Alto Hospital in San Antonio — NFPA 101, 99, 13, and 72 editions, smoke compartments, and EES.Section 1: Project OverviewUniversity…
Article
Meta Description: How sprinkler and alarm rules drive BIM coordination: NFPA 13 obstruction and clearance limits, NFPA 72 device spacing, clash detection, submittal alignment.Fire protection design rarely fails on the hy…